Panels For Data Centres
Mission-critical 2N and N+1 electrical distribution, power density, and granular branch circuit monitoring

Mission-Critical Data Centre Power Distribution
Nairobi Power Engineers engineers and manufactures specialized Power Distribution Units (PDUs), static transfer switch (STS) panels, and server hall distribution switchboards designed for Tier III and Tier IV data centres, telecoms landing stations, and colocation facilities across Kenya.
Featuring dual-bus 2N/N+1 compartmentalized Form 4b Type 7 separation, hot-swappable branch circuit monitoring systems (BCMS), and transient voltage surge suppression, our panels deliver continuous, high-availability uptime and granular energy analytics per rack.
Equipment & Range Highlights
Tier III / IV Ready • Form 4b
Server Hall Power Distribution Units (PDU)
High-density floor-standing PDU cubicles with isolation transformers, dual mains incomers, and modular branch circuit distribution.
Lovato DMG • Power Analytics
Lovato High-Accuracy Power Quality Analysers
Multi-function power meters monitoring individual server feeds for voltage sags, harmonics (THD), neutral currents, and power factor.
Data Centre Switchgear Specifications
| Parameter | Specification Details |
|---|---|
| Uptime Tier Architecture | Engineered for Tier II, Tier III (Concurrently Maintainable), Tier IV (Fault Tolerant) |
| Internal Compartmentalization | Form 4b Type 7 (individual metal barriers between busbars, units and terminals) |
| Busbar Current Ratings | 800 A, 1250 A, 1600 A, 2500 A (100 kA / 1s fault rating subject to assembly verification) |
| Neutral Conductor Sizing | 200% double-rated neutral busbars to absorb triplen harmonics (3rd, 9th, 15th) |
| Branch Circuit Monitoring | Individual current (A), voltage (V), power (kW), and energy (kWh) per server rack way |
| Network Management Protocol | SNMP v3, Modbus TCP/IP, BACnet IP for integration with DCIM software platforms |
Engineering & Build Highlights
- Neutral conductor capacity is selected after reviewing harmonic loading and thermal conditions.
- Internal separation supports segregation of functional units; it does not eliminate arc-flash risk or authorise live work. Maintenance requires an approved isolation and safety procedure.
- Specify withdrawable or replaceable units where required; replacement procedures depend on the selected equipment and approved isolation plan.
- Transient Voltage Surge Suppression (TVSS) Type 1+2 installed at both main and secondary distribution stages
- Infrared inspection viewing ports on all main busbar joints for non-invasive thermographic audits
- Integrated environmental sensors (temperature, humidity, door interlocks, smoke detection) connected via DCIM
Target Applications & Sectors
Design Your Data Centre Power Infrastructure
Consult with our critical facilities switchgear team for single-line diagrams, PDU layouts, and DCIM telemetry architectures.
Explore your requirements.
Try the tools relevant to panels for data centres, compare scenarios, then send the inputs to our team.
Enable JavaScript for live calculations, or ask our engineering team.
Connect your application to the right components.
Explore these related component families, compare exact manufacturer references and build a quotation request.
LOVATO manufacturer family images; exact configurations vary by model.
Send a BOQ or parts list