Automatic Power Factor Correction (APFC) Banks
Dynamic multi-step reactive power compensation engineered to maintain power factor > 0.98

Automatic Power Factor Correction (APFC)
Nairobi Power Engineers designs and builds custom Automatic Power Factor Correction (APFC) panelboards from 25 kvar to 1200 kvar. Our systems monitor instantaneous reactive power demand and automatically switch capacitor stages in and out to maintain a stable, compliant power factor (typically 0.98 – 0.99 lagging).
Built around the industry-leading Lovato Electric DCRG/DCRL controller family and Lovato BF...K damping contactors, our APFC banks feature self-healing metallized polypropylene capacitors, internal discharge resistors, step indicator lamps, and forced cooling.
Equipment & Range Highlights
Lovato Electric • Controller
Lovato DCRG8 Advanced APFC Controller
Microprocessor power factor controller with graphic backlit LCD, 8 to 16 relay step outputs, temperature sensing, and THD monitoring.
Lovato BF...K • Inrush Damping
Lovato Dedicated Capacitor Switching Contactors
Heavy-duty contactors with quick-break auxiliary contacts and pre-insertion damping resistors to suppress destructive capacitor inrush currents.
APFC Bank Technical Data
| Parameter | Specification Details |
|---|---|
| Total Bank Capacity Range | 25 kvar to 1200 kvar (modular step sizing: 5, 10, 25, 50, 100 kvar) |
| Capacitor Voltage Rating | 440 V / 480 V / 525 V continuous (50 Hz) |
| Discharge Resistors | Integral safety resistors discharge capacitors to < 50V within 60 seconds |
| Switching Technology | Lovato BF...K damping contactors or Thyristor Solid-State (for fast welding loads) |
| Target Power Factor | Programmable from 0.80 inductive to 0.80 capacitive (default 0.98 ind.) |
| Enclosure Construction | IP31 / IP43 / IP54 Sheet Steel RAL 7035 with thermostat exhaust fans |
Engineering & Build Highlights
- Microprocessor step balancing algorithms rotate step duty evenly to extend overall bank lifespan
- Lovato DCRG controller logs kvar step health and alerts when individual capacitor stages degrade
- Internal MCCB or switch-disconnector incomer with door interlocking for safe servicing
- Individual HRC fuse or MCB protection for each capacitor step ensures isolated fault clearance
- Thermostatically controlled forced ventilation prevents heat accumulation during full load duty
- External current transformer (CT) input (5A secondary) compatible with standard switchboard CTs
Target Applications & Sectors
Eliminate KPLC Penalties Today
Share your latest electricity bill with our power quality team for a measurement-based correction assessment and sizing proposal.
Explore your requirements.
Try the tools relevant to automatic power factor correction (apfc) banks, compare scenarios, then send the inputs to our team.
Enable JavaScript for live calculations, or ask our engineering team.
Connect your application to the right components.
Explore these related component families, compare exact manufacturer references and build a quotation request.
LOVATO manufacturer family images; exact configurations vary by model.
Send a BOQ or parts list