Main & Sub-Distribution Boards

Incoming, metering and outgoing distribution in one coordinated assembly

Main & Sub-Distribution Boards — engineering concept

Main & Sub-Distribution Boards

Distribution boards in Kenya — frequently called consumer units in homes or triple-pole and neutral (TPN) boards in commercial settings — safely split an incoming electrical supply into individual protected circuits. We take the incoming supply, meter it, and distribute protected outgoing ways to sub-boards and plant.

Main distribution boards (MDBs) receive bulk power from the utility transformer or standby generator and house the master ACB or MCCB incomer, revenue metering, surge protection and outgoing feeders. Sub-distribution boards (SDBs) branch off the MDB to serve specific floors, wings or zones. Final distribution boards (FDBs) are the end-point consumer units delivering power directly to socket, lighting and machine circuits.

We size the busbar, incomer and outgoing devices from the load schedule and the prospective fault level. Sub-distribution and final boards are built to the same standard in wall-mounted, floor-standing or free-standing formats. OEM selection can be coordinated across ABB, Schneider Electric and CHINT ranges.

Distribution Assemblies & Lineups

ABB MNS Digital low-voltage switchgear and motor control lineup
Tier 1 · Primary intakePictured: ABB MNS Digital low-voltage switchgear and motor control lineup.

Main Distribution Switchboards (MDB)

ABB MNS Digital is pictured as a primary-intake and motor-control lineup reference. NPE project assemblies are specified from the load schedule, prospective fault current and operating conditions; the photograph does not establish a particular current, fault or separation rating.

RolePrimary intake
AssemblyIEC 61439-1 / -2 scope
RatingsProject-specific verification
Explore Main Distribution Switchboards (MDB)
NHP Concept Plus wall-mounted distribution panelboard family
Tier 2 · Floor or zonePictured: NHP Concept Plus wall-mounted distribution panelboard family.

Sub-Distribution Switchboards (SDB)

The NHP Concept Plus family shows a wall-mounted panelboard with its accessory enclosure, suitable as a sub-distribution reference. This Australian AS/NZS 61439-3 range has isolator incomers up to 250 A or MCCB incomers up to 200 A; it is not a Form 4 main-switchboard lineup.

Isolator incomerUp to 250 A
MCCB incomerUp to 200 A
ReferenceNHP Concept Plus
Explore Sub-Distribution Switchboards (SDB)
Schneider Electric Easy9 EZ9EFS12CMCU consumer unit
Tier 3 · Final circuitsPictured: Schneider Electric Easy9 EZ9EFS12CMCU consumer unit.

Final Distribution Boards (FDB) & Consumer Units

The Schneider Electric Easy9 EZ9EFS12CMCU is a 12-way single-phase metal consumer-unit reference for final circuits. MCB, RCD and RCBO selection, loading and enclosure configuration must be confirmed for the actual board.

ConfigurationSingle phase + neutral
ReferenceEasy9 · 12-way
ProtectionSelect per circuit
Explore Final Distribution Boards (FDB) & Consumer Units

Distribution Board Classifications

Selection itemEngineering requirement
MDB · primary intakeMain incomer and feeders; determine assembly current, fault withstand and separation from the project. ABB MNS is a lineup reference.
SDB · floor or zoneDistributes selected outgoing feeders. Pictured NHP panelboard family is not an 800 A / Form 4 assembly.
FDB · final circuitsFeeds lighting, sockets and equipment through selected MCBs / RCBOs. Pictured Easy9 is a single-phase consumer unit.

Main & Sub-Distribution Boards Specs

Selection itemEngineering requirement
Assembly standardDetermine the applicable IEC 61439 part and obtain design-verification and routine-verification records for the supplied assembly.
Current and voltageFrom the approved load schedule, diversity, supply arrangement and service conditions.
Short-circuit performanceProspective fault current, duration, protective-device coordination and assembly verification must agree.
Separation and accessSpecify the required form and maintenance method. Internal separation does not authorise live work.
Enclosure and ambientSpecify IP rating, location, ventilation, temperature rise and cable access for the actual installation.
PhotographsManufacturer references illustrate equipment classes; ratings are not inferred from appearance.

Inside the Box

  • Incomer / main switch — isolates the entire electrical supply to the board (ACB, MCCB or rotary isolator)
  • MCBs (Miniature Circuit Breakers) — protect individual circuits from overloads and short circuits
  • RCDs and RCBOs — detect earth leakage faults (typically 30 mA) to prevent electric shocks. Modern setups favour RCBOs for individual circuit isolation
  • SPDs (Surge Protection Devices) — Type 1 + 2 arresters protecting sensitive electronics from voltage spikes
  • Copper busbars — distribute the incoming live current across individual breaker switches, braced to the prospective fault level
  • Neutral and earth bars — return current to the source and channel fault current safely to earth
  • Discrimination study so a fault clears at the nearest device only
  • Surge protection, metering chamber and spare ways as specified

Key Features

  • Copper busbar sized and braced to the prospective fault level
  • Incoming ACB or MCCB with adjustable protection settings
  • Discrimination and cascading verified against manufacturer tables
  • Form 2 to Form 4b internal separation selected for the project; maintenance requires an approved isolation procedure
  • Type-tested to IEC 61439 with assembly-specific fault-level verification
  • Modular and bespoke options for fixed or withdrawable functional units
  • Front and rear access with top or bottom cable entry
  • Intelligent options including touchscreen HMI and Modbus / Ethernet communications

Typical Applications

Office and retail developments Factories and process plant Hospitals, schools and campuses Water works and infrastructure sites Data centres and telecommunications Residential apartments and estates Construction sites (temporary boards) Hotels and hospitality complexes
An MDB receives the primary incoming supply and feeds major outgoing circuits. An SDB distributes power to a floor, zone or group of loads. An FDB supplies final circuits such as lighting and sockets. Current and fault ratings are selected for the project rather than fixed by these names.
Either. We engineer from your single line diagram and load schedule, or build to an approved consultant design and issue GA drawings for sign-off.
Confirm the required form of separation, prospective fault current, duration and verification records for the actual proposed assembly. A reference photograph does not establish these ratings, and internal separation does not authorise live maintenance.
Typical lead time runs from drawing approval; standard boards are quicker than Form 4 lineups with imported ACBs. We confirm the programme with the quotation.
Testing requirements and records are agreed for each assembly. Ask the team to confirm the applicable IEC 61439 checks for your scope.
Confirm the required form of separation, prospective fault current, duration and verification records for the actual proposed assembly. A reference photograph does not establish these ratings, and internal separation does not authorise live maintenance.

Specify a Main & Sub-Distribution Board

Confirm compatibility and availability against your project brief before you specify.

Discuss Your Requirement

Explore your requirements.

Try the tools relevant to main & sub-distribution boards, compare scenarios, then send the inputs to our team.

Enable JavaScript for live calculations, or ask our engineering team.

Conceptual engineering scenes illustrate applications. Manufacturer reference photos are identified separately. Confirm exact models, dimensions and ratings before ordering.

Connect your application to the right components.

Explore these related component families, compare exact manufacturer references and build a quotation request.

Open the E-Shop

LOVATO manufacturer family images; exact configurations vary by model.

Send a BOQ or parts list

Continue the specification

Application and selection guides

Related engineering methods