Protect
MCB, RCBO, RCD, isolator and SPD selection
Product detail

Product snapshot
Contractor-ready final DBs, wiring accessories, enclosures, containment and termination hardware.
MCB, RCBO, RCD, isolator and SPD selection
Consumer units, DBs and IP-rated boxes
Cable tray, trunking and DIN rail layout
Lugs, glands, ferrules and labelled bars
Final circuits
SPN/TPN boards, MCBs, RCBOs, RCDs and SPD options
Accessories
Switches, sockets, isolators, dimmers and sensors
Enclosures
IP54/IP65 metal or plastic boxes, DIN rails and plates
Terminations
Lugs, glands, ferrules, terminal bars and trunking
Final sub-distribution and installation components — domestic consumer units, commercial distribution boards, modular switches, sockets, smart accessories, and electrical supplies.
Nairobi Power Engineers designs and manufactures the assembly around site duty, prospective fault level, installation access, service continuity, cable entry and maintainability. The supply can be configured with ABB, Schneider Electric or CHINT equipment according to duty, lead time and lifecycle support.
All aspects of the design are detailed in 2D and 3D CAD options. Distribution assemblies are available to the same specification across main, sub-main and final-board levels.
OEM selection basis
Technical detail library
Filter the relevant component trading lines and bespoke assemblies for this product family by market segment. Open the cards for ratings, source basis, build options and direct contact links.
Engineering Calculator
Enter parameters for real-time IEC/KPLC-standard sizing. Results update dynamically.
Sizing results
Main Switch Rating
-
DB Enclosure Size
-
Suggested RCBOs
-
Main Cable Feed
-
* For reference only. NPE engineering verifies configurations prior to build.
Our Wiring Accessories & Supplies solutions are custom-engineered and assembled locally at our Baricho Road workshop in Nairobi. A standard build includes high-quality modular enclosures, premium copper busbars (rated for local environmental conditions), type-tested circuit breakers or control elements from trusted global partners (ABB, Schneider Electric and CHINT), and comprehensive routine test certifications before delivery.
All assemblies comply with KEBS and EPRA regulations. You should confirm the required operational voltage (typically 415V three-phase or 240V single-phase in Kenya), rated current, prospective fault levels (e.g., 35kA or 50kA as per KPLC system requirements), form of separation (up to Form 4b), IP rating (IP31 indoor / IP54 for dust-heavy sites), and cable entry orientation (top or bottom entry).
NPE starts with the single-line diagram, load schedule and operating sequence, then selects the circuit protection path, device families, enclosure format, controls and testing requirements.
Send the single-line diagram, load schedule, incoming supply details, fault level if known, preferred OEM brand, cable entry direction, installation environment and delivery location.
Yes. NPE can quote ABB, Schneider Electric, CHINT or a mixed-OEM architecture according to rating, availability, monitoring requirement, lifecycle support and budget.
Yes. Metering, alarms, Modbus, Ethernet, BMS contacts, SCADA points and commissioning checks can be included where the selected product family supports them.
Product enquiry
Use the calculators for a first-pass engineering check, then send us the SLD and load schedule for a project-ready selection.
Wiring accessories and installation supplies are picked against your schedule of quantities, checked at our Baricho Road workshop stores, and delivered with the brand and rating documentation your electrician expects. Use the enquiry routes above for a priced list, or the form alongside to schedule an engineer.
Electrical service you can count on
When wiring accessories and supplies equipment fails, you need fast, reliable help from experienced engineers. We offer around-the-clock emergency support across Nairobi and East Africa — keeping your plant safe and powered, day or night. Whether it is an urgent breakdown or a scheduled repair, our team is ready to respond whenever you need us.
Wiring accessories costs vary significantly depending on several key factors. Here is what you need to know to make informed decisions and avoid unexpected expenses.
The price of a wiring accessories package depends on the load schedule, fault level, enclosure form and IP rating, plus the OEM equipment you specify. Site conditions and delivery timelines also move the number.
Our engineers issue itemised quotations covering equipment, assembly, factory testing and delivery — no hidden fees. You know exactly what to expect before any work begins.
Scheduled inspection, thermographic surveys and torque checks catch small issues early, helping you avoid major repairs. Planned maintenance extends system life and protects uptime.
Whether it is a scheduled upgrade or an urgent call, our Nairobi workshop at Baricho Road responds quickly and gets the job done right — minimising downtime and keeping you safe.
If you are ever unsure or feel unsafe around an energised assembly, do not take chances — call a licensed engineer. Safety always comes first. Feel free to contact us or give us a call.
+254 0737-944-014