Incomer

ACB/MCCB intake and metering

02

Busbar

Horizontal and vertical distribution

03

Buckets

Fixed, plug-in or withdrawable feeders

04

Gateway

PLC, BMS and status signals

Power path

Incomer, busbar, starter tiers and cable alley

Feeder format

Fixed, plug-in or withdrawable starter modules

Protection

MPCB/MCCB, overload, earth, phase and short-circuit

Maintenance

Segregation, isolation, labels and test records

Read more

Type-tested MCC architecture for Kenyan factories, water works, campuses and process plants, with fixed, plug-in or withdrawable starters, segregated busbars and maintainable cable alleys.

Nairobi Power Engineers designs and manufactures the assembly around site duty, prospective fault level, installation access, service continuity, cable entry and maintainability. The supply can be configured with ABB, Schneider Electric or CHINT equipment according to duty, lead time and lifecycle support.

MCC designs are documented with incomer ratings, busbar sizing, starter schedule, segregation form, cable-alley layout, control wiring, metering points and routine verification records.

  • MCC incomer, busbar, starter tier and cable-alley architecture
  • Fixed, plug-in or withdrawable starter modules for pumps, conveyors, fans and compressors
  • Form 2/Form 4 segregation, top or bottom cable entry and front or rear access planning
  • ACB/MCCB incomers, horizontal and vertical busbars, metering, PLC and SCADA gateway sections
  • Incomer rating, prospective fault level and busbar sizing
  • Starter type, motor FLC, duty cycle and feeder protection coordination
  • Segregation form, access direction, cable-entry route and spare-way allowance
  • Metering, PLC, SCADA, BMS and maintenance-isolation requirements

OEM selection basis

ABB, Schneider Electric and CHINT fit where they genuinely belong.

  • ABB MNS-MCC architecture for high-availability process applications.
  • Schneider Model 6 MCC and TeSys control devices for integrated motor-control and automation.
  • CHINT contactors, MPCBs, relays and pilot devices for value-engineered feeder buckets.
  • NPE-fabricated MCC sections configured for Nairobi-based maintenance and spares access.

Technical detail library

Product Range & Target Markets, Switchboard Features and Options:

MCC rows only: incomers, busbars, fixed or withdrawable starters, feeder modules, metering, PLC gateways and cable-alley hardware. Open the cards for ratings, source basis, build options and direct contact links.

Engineering Calculator

Instant Technical Sizing

Enter parameters for real-time IEC/KPLC-standard sizing. Results update dynamically.

Sizing results

Estimated FLA

-

Main Contactor

-

Overload Range

-

Suggested Frame

-

* For reference only. NPE engineering verifies configurations prior to build.

Frequently Asked Questions

What is included in Motor Control Centres (MCC)?

Our Motor Control Centres (MCC) solutions are custom-engineered and assembled locally at our Baricho Road workshop in Nairobi. A standard build includes high-quality modular enclosures, premium copper busbars (rated for local environmental conditions), type-tested circuit breakers or control elements from trusted global partners (ABB, Schneider Electric and CHINT), and comprehensive routine test certifications before delivery.

Which standards and ratings should be confirmed?

All assemblies comply with KEBS and EPRA regulations. You should confirm the required operational voltage (typically 415V three-phase or 240V single-phase in Kenya), rated current, prospective fault levels (e.g., 35kA or 50kA as per KPLC system requirements), form of separation (up to Form 4b), IP rating (IP31 indoor / IP54 for dust-heavy sites), and cable entry orientation (top or bottom entry).

How does NPE choose the product architecture?

NPE starts with the single-line diagram, load schedule and operating sequence, then selects the motor control path, device families, enclosure format, controls and testing requirements.

What information does NPE need to quote Motor Control Centres (MCC)?

Send the single-line diagram, load schedule, incoming supply details, fault level if known, preferred OEM brand, cable entry direction, installation environment and delivery location.

Can NPE supply ABB, Schneider Electric and CHINT options?

Yes. NPE can quote ABB, Schneider Electric, CHINT or a mixed-OEM architecture according to rating, availability, monitoring requirement, lifecycle support and budget.

Can the system include monitoring and remote signals?

Yes. Metering, alarms, Modbus, Ethernet, BMS contacts, SCADA points and commissioning checks can be included where the selected product family supports them.

Product enquiry

Do you have a Motor Control Centres (MCC) enquiry? Get in touch...

Use the calculators for a first-pass engineering check, then send us the SLD and load schedule for a project-ready selection.

Built and supported in Nairobi

Every motor control centre NPE builds is specified against the incomer rating and feeder schedule, assembled and inspected at our Baricho Road workshop, and handed over with the drawings and test records your consultant expects. Use the enquiry routes above for a sized quotation, or the form alongside to schedule an engineer.

24/7 Emergency Support

Electrical service you can count on

When motor control centres equipment fails, you need fast, reliable help from experienced engineers. We offer around-the-clock emergency support across Nairobi and East Africa — keeping your plant safe and powered, day or night. Whether it is an urgent breakdown or a scheduled repair, our team is ready to respond whenever you need us.

Cost and Estimates

Motor Control Centre costs vary significantly depending on several key factors. Here is what you need to know to make informed decisions and avoid unexpected expenses.

What Affects the Cost?

The price of a Motor Control Centre package depends on the load schedule, fault level, enclosure form and IP rating, plus the OEM equipment you specify. Site conditions and delivery timelines also move the number.

Get a Detailed Estimate

Our engineers issue itemised quotations covering equipment, assembly, factory testing and delivery — no hidden fees. You know exactly what to expect before any work begins.

Smart Maintenance

Scheduled inspection, thermographic surveys and torque checks catch small issues early, helping you avoid major repairs. Planned maintenance extends system life and protects uptime.

Fast, Reliable Response

Whether it is a scheduled upgrade or an urgent call, our Nairobi workshop at Baricho Road responds quickly and gets the job done right — minimising downtime and keeping you safe.

When in doubt, put safety first

If you are ever unsure or feel unsafe around an energised assembly, do not take chances — call a licensed engineer. Safety always comes first. Feel free to contact us or give us a call.

+254 0737-944-014

How to stay safe during an electrical emergency

Overheating or Burning Smell
Isolate the supply if it is safe to do so, keep people clear of the panel and call us immediately. A burning smell around an enclosure usually indicates a loose termination or an overloaded circuit and must never be left running.
Nuisance Tripping
Repeated tripping is a symptom, not the fault. It usually points to overload, an earth leakage path or a device sized incorrectly for the duty. We test the circuit, verify discrimination and correct the root cause rather than resetting the device.
Safe Isolation and Access
Only competent, authorised personnel should open a live assembly. Follow lock-off and permit-to-work procedures, and use the correct PPE and rated test equipment for the fault level of the installation.
Routine Inspection Intervals
We recommend periodic inspection and testing in line with the KS/IEC regime for your installation category, with thermographic scanning on critical boards. We can hold the schedule for you and report against it.