Cable sized correctly for the circuit

Nairobi Power Engineers supplies LV power, control, armoured and flexible cables, sized to IEC for the design current, the installation conditions and the acceptable voltage drop.

The correct conductor size depends on more than the current: the ambient temperature, the installation method and any harmonics reduce the cable’s capacity, so the conductor must be sized on its installed condition — not just the breaker rating.

Use the calculator on this page to see the recommended copper cable size for a load, with ambient and installation derating applied the right way round.

24/7 Emergency Support

Electrical service you can count on

When cable equipment fails, you need fast, reliable help from experienced engineers. We offer around-the-clock emergency support across Nairobi and East Africa — keeping your plant safe and powered, day or night. Whether it is an urgent breakdown or a scheduled repair, our team is ready to respond whenever you need us.

Cost and Estimates

What drives the cost

What affects the cost?

Conductor size and material (copper or aluminium), armour and insulation type, and the run length. Derating for ambient, grouping and installation method changes the size needed.

Get a detailed estimate

We quote the cable to the circuit — size, type and length — with the sizing calculation behind it.

Sized on installed condition

Ambient temperature, installation method and harmonics reduce the cable’s capacity, so the conductor is sized above the current accordingly.

Voltage drop checked

On long runs the voltage drop is checked and the conductor upsized where needed, not just the current capacity.

Product Family

Select the range for the job

Engineering Calculator

Instant Technical Sizing

Enter parameters for real-time IEC/KPLC-standard sizing. Results update dynamically.

Results

Design Current

Recommended Breaker

Recommended Type

Copper Cable Size

* For reference only. NPE engineering verifies configurations prior to build.

Frequently asked questions

How is cable size chosen?
From the design current, then increased so the cable’s derated capacity still carries it, and checked for voltage drop on long runs. The calculator on this page shows the size.
Copper or aluminium?
Copper for most LV circuits and smaller sizes; aluminium can be economical on large feeders where the size increase is acceptable.
Does derating change the cable or the breaker?
The cable. Derating reduces the cable’s capacity so the conductor grows; the breaker is sized on the load, not the derating.
When do I need armoured cable?
For buried runs and where mechanical protection is needed; SWA armoured cable is the usual choice.