Protection
MCCB/MPCB and input isolation
Product detail

Product snapshot
Speed control panels with protection, bypass, filtering and BMS/PLC feedback.
MCCB/MPCB and input isolation
Speed, torque and ramp profile
Reactor, EMC and dV/dt review
Setpoint, run, fault and energy data
Drive duty
Torque curve, overload and speed-control range
Power quality
Reactors, EMC filters, dV/dt and harmonic review
Thermal design
Panel heat load, fan/filter and derating check
Integration
Modbus, Ethernet, BMS, PLC and bypass logic
VFD panels for pumps, fans, conveyors, extruders and compressors where speed control, energy performance, soft starting and process stability matter.
Nairobi Power Engineers designs and manufactures the assembly around site duty, prospective fault level, installation access, service continuity, cable entry and maintainability. The supply can be configured with ABB, Schneider Electric or CHINT equipment according to duty, lead time and lifecycle support.
VFD panel designs include drive sizing, overload duty, reactor/filter selection, bypass logic, heat-load calculations, ventilation, cable-length review and BMS/PLC signal mapping.
OEM selection basis
Technical detail library
VFD rows only: drive feeders, bypass panels, reactors, EMC filters, ventilation and Modbus/BMS integration hardware. Open the cards for ratings, source basis, build options and direct contact links.
Engineering Calculator
Enter parameters for real-time IEC/KPLC-standard sizing. Results update dynamically.
Sizing results
Estimated FLA
-
Main Contactor
-
Overload Range
-
Suggested Frame
-
* For reference only. NPE engineering verifies configurations prior to build.
Our Variable Frequency Drive (VFD) Panels solutions are custom-engineered and assembled locally at our Baricho Road workshop in Nairobi. A standard build includes high-quality modular enclosures, premium copper busbars (rated for local environmental conditions), type-tested circuit breakers or control elements from trusted global partners (ABB, Schneider Electric and CHINT), and comprehensive routine test certifications before delivery.
All assemblies comply with KEBS and EPRA regulations. You should confirm the required operational voltage (typically 415V three-phase or 240V single-phase in Kenya), rated current, prospective fault levels (e.g., 35kA or 50kA as per KPLC system requirements), form of separation (up to Form 4b), IP rating (IP31 indoor / IP54 for dust-heavy sites), and cable entry orientation (top or bottom entry).
NPE starts with the single-line diagram, load schedule and operating sequence, then selects the motor control path, device families, enclosure format, controls and testing requirements.
Send the single-line diagram, load schedule, incoming supply details, fault level if known, preferred OEM brand, cable entry direction, installation environment and delivery location.
Yes. NPE can quote ABB, Schneider Electric, CHINT or a mixed-OEM architecture according to rating, availability, monitoring requirement, lifecycle support and budget.
Yes. Metering, alarms, Modbus, Ethernet, BMS contacts, SCADA points and commissioning checks can be included where the selected product family supports them.
Product enquiry
Use the calculators for a first-pass engineering check, then send us the SLD and load schedule for a project-ready selection.
Every VFD panel NPE builds is sized against the driven load, assembled with the reactors and filtering the installation needs, and bench-tested at our Baricho Road workshop before dispatch. Use the enquiry routes above for a sized quotation, or the form alongside to schedule an engineer.
Electrical service you can count on
When variable frequency drives equipment fails, you need fast, reliable help from experienced engineers. We offer around-the-clock emergency support across Nairobi and East Africa — keeping your plant safe and powered, day or night. Whether it is an urgent breakdown or a scheduled repair, our team is ready to respond whenever you need us.
VFD panel costs vary significantly depending on several key factors. Here is what you need to know to make informed decisions and avoid unexpected expenses.
The price of a VFD panel package depends on the load schedule, fault level, enclosure form and IP rating, plus the OEM equipment you specify. Site conditions and delivery timelines also move the number.
Our engineers issue itemised quotations covering equipment, assembly, factory testing and delivery — no hidden fees. You know exactly what to expect before any work begins.
Scheduled inspection, thermographic surveys and torque checks catch small issues early, helping you avoid major repairs. Planned maintenance extends system life and protects uptime.
Whether it is a scheduled upgrade or an urgent call, our Nairobi workshop at Baricho Road responds quickly and gets the job done right — minimising downtime and keeping you safe.
If you are ever unsure or feel unsafe around an energised assembly, do not take chances — call a licensed engineer. Safety always comes first. Feel free to contact us or give us a call.
+254 0737-944-014