The math we use, made available to you.

Professional estimation tools for electrical contractors and designers. Calculate critical specifications for low-voltage installations. Formulas align with IEC/BS 7671.

Preliminary Use Only

Calculators provide estimates under standard conditions. Verify specifications against current IEC/BS 7671 regulations with an NPE design engineer.

Request a Custom Spec

Cable Sizing

IEC 60364 Copper Conductor

Determine minimum conductor size based on continuous currents, phase connections, installation methods, and thermal grouping factors.

⚡ Output — Calculated Results

Adjusted current

Min Conductor

Breaker size

⚡ Accessories & Technical Specs Click to expand

⚡ Ratings

🛠️ Accessories

🔍 Filters & Details

kVA ↔ Amps

Bidirectional Converter

Convert electrical load values between kVA and Line Amps across single phase, split phase, or polyphase industrial supplies.

⚡ Output — Calculated Results

Equivalent Amps

Active Power

Reactive Load

⚡ Accessories & Technical Specs Click to expand

⚡ Ratings

🛠️ Accessories

🔍 Filters & Details

Capacitor Bank Sizing

Power Factor Correction

Calculate the required reactive power (kVAR) steps to stabilize system phase lag, raise power factor, and eliminate reactive load penalties.

⚡ Output — Calculated Results

Required kVAR

Standard Bank

Target Current

⚡ Accessories & Technical Specs Click to expand

⚡ Ratings

🛠️ Accessories

🔍 Filters & Details

M

Motor Starting Current

Inrush Estimator

Estimate full-load current (FLC) and transient peak starting current based on motor starter type (DOL, Star-Delta, Soft-Starter).

⚡ Output — Calculated Results

Full-Load (FLC)

Starting Current

Rec. protection

⚡ Accessories & Technical Specs Click to expand

⚡ Ratings

🛠️ Accessories

🔍 Filters & Details

Standby Generator Sizing

Connected Load & Motor Starting

Size diesel standby power generators correctly, integrating connected load diversity profiles and motor startup power surges.

⚡ Output — Calculated Results

Required Load

Standard generator

Amps capacity

⚡ Accessories & Technical Specs Click to expand

⚡ Ratings

🛠️ Accessories

🔍 Filters & Details

Voltage Drop

Single/Three Phase

Verify that operational voltage drop along feeder cables does not exceed the standard 4% IEC regulatory boundary.

⚡ Output — Calculated Results

Voltage Drop

Percentage Drop

IEC Status

⚡ Accessories & Technical Specs Click to expand

⚡ Ratings

🛠️ Accessories

🔍 Filters & Details

Short-Circuit Current

Prospective Fault

Estimate prospective short circuit current (Isc) downstream of your utility transformer to verify switchgear breaking capacity requirements.

⚡ Output — Calculated Results

Transformer FLC

Fault Current

Breaking Capacity

⚡ Accessories & Technical Specs Click to expand

⚡ Ratings

🛠️ Accessories

🔍 Filters & Details

Earthing Conductor

IEC 60364 Sizing

Size minimum protective grounding conductor cross-sections to safely handle fault energy dissipation without thermal damage.

⚡ Output — Calculated Results

Min Ground CSA

Standard CSA

Terminations

⚡ Accessories & Technical Specs Click to expand

⚡ Ratings

🛠️ Accessories

🔍 Filters & Details

Busbar Sizing

Cross-Section Estimator

Obtain standard copper or aluminium flat rectangular busbar layout recommendations based on nominal switchboard current capacity.

⚡ Output — Calculated Results

Required Area

Suggested Bar

Standoff Span

⚡ Accessories & Technical Specs Click to expand

⚡ Ratings

🛠️ Accessories

🔍 Filters & Details

Lighting Lumen Method

Fixture Count Estimator

Estimate total luminaire fixture count required to achieve targeted lighting lux parameters across indoor working spaces.

⚡ Output — Calculated Results

Fixtures Required

Total Load

Load Current

⚡ Accessories & Technical Specs Click to expand

⚡ Ratings

🛠️ Accessories

🔍 Filters & Details

UPS Battery Sizing

Backup Autonomy

Determine target lead-acid or lithium battery battery bank AH rating and DC circuit breaker protection for standby UPS backup loads.

⚡ Output — Calculated Results

Required Capacity

Storage energy

DC Breaker Size

⚡ Accessories & Technical Specs Click to expand

⚡ Ratings

🛠️ Accessories

🔍 Filters & Details

Solar PV Sizing

Off-Grid Estimator

Size off-grid solar panels array peak rating, storage battery capacity, and hybrid solar power inverter rating based on load consumption.

⚡ Output — Calculated Results

Array Sizing

Panels Required

Inverter rating

⚡ Accessories & Technical Specs Click to expand

⚡ Ratings

🛠️ Accessories

🔍 Filters & Details

MCB/MCCB/ACB Sizing

Circuit Breaker selector

Calculate design current and select appropriate nominal breaker rating, frame size (MCB, MCCB, ACB), and tripping curves.

⚡ Output — Calculated Results

Nominal rating

Breaker Frame

Tripping Curve

⚡ Accessories & Technical Specs Click to expand

⚡ Ratings

🛠️ Accessories

🔍 Filters & Details