+254 0737-944-014 WhatsApp sales@nairobipower.co.ke
Nairobi Power Engineers Ltd (NPE) logo Nairobi Power Engineers

Earth Leakage Relays

Product detail

Industrial circuit breaker detail inside an LV distribution panel

Product snapshot

Earth Leakage Relays

Adjustable earth-leakage relay and toroid schemes for industrial feeders and MCC compartments.

01

Toroid

Core-balance CT size and cable routing

02

Trip delay

Adjustable threshold and delay selectivity

03

Trip path

MCCB, ACB, contactor or alarm interface

04

Commission

Test/reset wiring and leakage verification

Sensitivity

30mA - 30A adjustable earth-leakage relay class

Delay

0 - 5s trip-delay coordination where applicable

Mounting

DIN rail, panel mount or surface-mount relay/toroid schemes

Interface

Breaker shunt trip, contactor trip, alarm or reset circuit

Read more

Earth-leakage relay and toroid protection for industrial feeders, mining-style duties, pump panels, MCC compartments and installations needing adjustable leakage current and trip delay.

Nairobi Power Engineers designs and manufactures the assembly around site duty, prospective fault level, installation access, service continuity, cable entry and maintainability. The supply can be configured with ABB, Schneider Electric or CHINT equipment according to duty, lead time and lifecycle support.

Earth-leakage relay schemes are documented with toroid size, cable routing, threshold, delay, trip/alarm interface, reset circuit and commissioning test procedure.

  • Earth-leakage relay panels for MCCB, ACB, contactor or shunt-trip disconnection schemes
  • DIN-rail, panel-mount and surface-mount relay/toroid arrangements
  • Adjustable leakage sensitivity and time-delay settings for selectivity and process continuity
  • Type A and Type B review where electronic drives, inverters or DC leakage components are present
  • Toroid size, cable routing, neutral treatment and shield bonding
  • Trip threshold, alarm threshold and time-delay coordination
  • Breaker shunt-trip, contactor trip or alarm-only interface design
  • Test/reset wiring, indication, maintenance access and commissioning procedure

OEM selection basis

ABB, Schneider Electric and CHINT fit where they genuinely belong.

  • ABB earth-fault and leakage interfaces for protection and monitoring schemes.
  • Schneider residual-current monitoring and relay interfaces for LV systems.
  • CHINT relay and shunt-trip interfaces for practical industrial protection panels.
  • NPE selection basis: earth-leakage relays support DIN/panel/surface mounting, Type A/B applications, 30mA to 30A sensitivity settings and delay ranges for coordination.

Technical detail library

Product Range & Target Markets, Switchboard Features and Options:

Earth-leakage rows only: relay/toroid sets, DIN or panel mounting, Type A/B duties, trip delay settings and alarm interfaces. Open the cards for ratings, source basis, build options and direct contact links.

Engineering Calculator

Instant Technical Sizing

Enter parameters for real-time IEC/KPLC-standard sizing. Results update dynamically.

Sizing results

Design Current

-

Recommended Breaker

-

Recommended Type

-

Copper Cable Size

-

* For reference only. NPE engineering verifies configurations prior to build.

Frequently Asked Questions

What is included in Earth Leakage Relays?

Our Earth Leakage Relays solutions are custom-engineered and assembled locally at our Baricho Road workshop in Nairobi. A standard build includes high-quality modular enclosures, premium copper busbars (rated for local environmental conditions), type-tested circuit breakers or control elements from trusted global partners (ABB, Schneider Electric and CHINT), and comprehensive routine test certifications before delivery.

Which standards and ratings should be confirmed?

All assemblies comply with KEBS and EPRA regulations. You should confirm the required operational voltage (typically 415V three-phase or 240V single-phase in Kenya), rated current, prospective fault levels (e.g., 35kA or 50kA as per KPLC system requirements), form of separation (up to Form 4b), IP rating (IP31 indoor / IP54 for dust-heavy sites), and cable entry orientation (top or bottom entry).

How does NPE choose the product architecture?

NPE starts with the single-line diagram, load schedule and operating sequence, then selects the circuit protection path, device families, enclosure format, controls and testing requirements.

What information does NPE need to quote Earth Leakage Relays?

Send the single-line diagram, load schedule, incoming supply details, fault level if known, preferred OEM brand, cable entry direction, installation environment and delivery location.

Can NPE supply ABB, Schneider Electric and CHINT options?

Yes. NPE can quote ABB, Schneider Electric, CHINT or a mixed-OEM architecture according to rating, availability, monitoring requirement, lifecycle support and budget.

Can the system include monitoring and remote signals?

Yes. Metering, alarms, Modbus, Ethernet, BMS contacts, SCADA points and commissioning checks can be included where the selected product family supports them.

Product enquiry

Do you have a Earth Leakage Relays enquiry? Get in touch...

Use the calculators for a first-pass engineering check, then send us the SLD and load schedule for a project-ready selection.

24/7 Emergency Support

Electrical service you can count on

When earth leakage protection equipment fails, you need fast, reliable help from experienced engineers. We offer around-the-clock emergency support across Nairobi and East Africa — keeping your plant safe and powered, day or night. Whether it is an urgent breakdown or a scheduled repair, our team is ready to respond whenever you need us.

Cost and Estimates

Earth leakage relay costs vary significantly depending on several key factors. Here is what you need to know to make informed decisions and avoid unexpected expenses.

What Affects the Cost?

The price of a earth leakage relay package depends on the load schedule, fault level, enclosure form and IP rating, plus the OEM equipment you specify. Site conditions and delivery timelines also move the number.

Get a Detailed Estimate

Our engineers issue itemised quotations covering equipment, assembly, factory testing and delivery — no hidden fees. You know exactly what to expect before any work begins.

Smart Maintenance

Scheduled inspection, thermographic surveys and torque checks catch small issues early, helping you avoid major repairs. Planned maintenance extends system life and protects uptime.

Fast, Reliable Response

Whether it is a scheduled upgrade or an urgent call, our Nairobi workshop at Baricho Road responds quickly and gets the job done right — minimising downtime and keeping you safe.

When in doubt, put safety first

If you are ever unsure or feel unsafe around an energised assembly, do not take chances — call a licensed engineer. Safety always comes first. Feel free to contact us or give us a call.

+254 0737-944-014

How to stay safe during an electrical emergency

Overheating or Burning Smell
Isolate the supply if it is safe to do so, keep people clear of the panel and call us immediately. A burning smell around an enclosure usually indicates a loose termination or an overloaded circuit and must never be left running.
Nuisance Tripping
Repeated tripping is a symptom, not the fault. It usually points to overload, an earth leakage path or a device sized incorrectly for the duty. We test the circuit, verify discrimination and correct the root cause rather than resetting the device.
Safe Isolation and Access
Only competent, authorised personnel should open a live assembly. Follow lock-off and permit-to-work procedures, and use the correct PPE and rated test equipment for the fault level of the installation.
Routine Inspection Intervals
We recommend periodic inspection and testing in line with the KS/IEC regime for your installation category, with thermographic scanning on critical boards. We can hold the schedule for you and report against it.