ACB duty
Main incomer, bus coupler or high-current feeder
Product detail

Product snapshot
Main LV incomer and bus-coupler ACBs for high-current switchboards up to 6300A class.
Main incomer, bus coupler or high-current feeder
LSIG protection, metering and communications
Fixed or withdrawable service strategy
Fault level, selectivity and routine test evidence
Current class
800A - 6300A ACB incomer, feeder or bus coupler duty
Trip unit
LSIG, earth fault, metering and communication options
Build format
Fixed or withdrawable, interlocked and form-segregated
Use case
MDB intake, generator incomer, bus section and critical LV power
High-capacity air circuit breaker incomers, bus couplers and main outgoing feeders for large LV switchboards, hospitals, malls, factories, data centres and infrastructure sites in Kenya.
Nairobi Power Engineers designs and manufactures the assembly around site duty, prospective fault level, installation access, service continuity, cable entry and maintainability. The supply can be configured with ABB, Schneider Electric or CHINT equipment according to duty, lead time and lifecycle support.
ACB selections are documented with incomer rating, prospective fault level, trip-unit functions, withdrawable/fixed format, bus coupler logic, interlocks, metering and selectivity evidence.
OEM selection basis
Technical detail library
ACB rows only: incomers, bus couplers, withdrawable cassettes, electronic trip units, interlocks and main-board accessories. Open the cards for ratings, source basis, build options and direct contact links.
Engineering Calculator
Enter parameters for real-time IEC/KPLC-standard sizing. Results update dynamically.
Sizing results
Design Current
-
Recommended Breaker
-
Recommended Type
-
Copper Cable Size
-
* For reference only. NPE engineering verifies configurations prior to build.
Our Air Circuit Breakers (ACB) solutions are custom-engineered and assembled locally at our Baricho Road workshop in Nairobi. A standard build includes high-quality modular enclosures, premium copper busbars (rated for local environmental conditions), type-tested circuit breakers or control elements from trusted global partners (ABB, Schneider Electric and CHINT), and comprehensive routine test certifications before delivery.
All assemblies comply with KEBS and EPRA regulations. You should confirm the required operational voltage (typically 415V three-phase or 240V single-phase in Kenya), rated current, prospective fault levels (e.g., 35kA or 50kA as per KPLC system requirements), form of separation (up to Form 4b), IP rating (IP31 indoor / IP54 for dust-heavy sites), and cable entry orientation (top or bottom entry).
NPE starts with the single-line diagram, load schedule and operating sequence, then selects the circuit protection path, device families, enclosure format, controls and testing requirements.
Send the single-line diagram, load schedule, incoming supply details, fault level if known, preferred OEM brand, cable entry direction, installation environment and delivery location.
Yes. NPE can quote ABB, Schneider Electric, CHINT or a mixed-OEM architecture according to rating, availability, monitoring requirement, lifecycle support and budget.
Yes. Metering, alarms, Modbus, Ethernet, BMS contacts, SCADA points and commissioning checks can be included where the selected product family supports them.
Product enquiry
Use the calculators for a first-pass engineering check, then send us the SLD and load schedule for a project-ready selection.
Electrical service you can count on
When air circuit breakers equipment fails, you need fast, reliable help from experienced engineers. We offer around-the-clock emergency support across Nairobi and East Africa — keeping your plant safe and powered, day or night. Whether it is an urgent breakdown or a scheduled repair, our team is ready to respond whenever you need us.
Air Circuit Breaker costs vary significantly depending on several key factors. Here is what you need to know to make informed decisions and avoid unexpected expenses.
The price of a Air Circuit Breaker package depends on the load schedule, fault level, enclosure form and IP rating, plus the OEM equipment you specify. Site conditions and delivery timelines also move the number.
Our engineers issue itemised quotations covering equipment, assembly, factory testing and delivery — no hidden fees. You know exactly what to expect before any work begins.
Scheduled inspection, thermographic surveys and torque checks catch small issues early, helping you avoid major repairs. Planned maintenance extends system life and protects uptime.
Whether it is a scheduled upgrade or an urgent call, our Nairobi workshop at Baricho Road responds quickly and gets the job done right — minimising downtime and keeping you safe.
If you are ever unsure or feel unsafe around an energised assembly, do not take chances — call a licensed engineer. Safety always comes first. Feel free to contact us or give us a call.