Precision Current Transformers (CTs)

Solid-core, busbar, split-core, and summing current transformers for switchgear metering and protection

Overview

Precision Current Transformers (CTs)

Accurate power metering, energy management, and overcurrent protection require high-precision current transformers that step down high primary busbar currents to standardized 5A or 1A secondary signals. Nairobi Power Engineers supplies the full line of Lovato Electric DMK series current transformers.

Available in solid-core ring types, rectangular busbar pass-through windows, and easy-install split-core configurations, our CTs feature Class 0.5, Class 0.5s, and Class 0.2s measurement accuracy, sealable terminal covers, and robust flame-retardant housings.

Product Lineup

Equipment & Range Highlights

Solid-Core Busbar Current Transformers Lovato DMK • Busbar / Cable

Solid-Core Busbar Current Transformers

Precision solid-core CTs with integrated busbar clamps and DIN-rail mounting accessories, certified for accuracy Class 0.5 and Class 0.2s.

Primary Current50 A up to 4000 A
Secondary5 A • 1 A
AccuracyClass 0.5 • Class 0.2s
Split-Core Current Transformers for Retrofits Retrofit • Split-Core Clamp

Split-Core Current Transformers for Retrofits

Clamp-on split-core CTs with push-latch magnetic cores allowing fast installation around existing live conductors without cable unbolting.

InstallationClip-On / Retrofit
Ratios100/5A to 2000/5A
SafetyNo Cable Disconnection
CT Specs

Current Transformer Technical Reference

CT FamilyPrimary Current SpectrumAccuracy Class & BurdenWindow Dimensions
Lovato DMK 1T50 A – 300 A (Cable Ring)Class 0.5 / Class 1 (2.5VA – 5VA)21 mm diameter cable hole
Lovato DMK 2T100 A – 600 A (Busbar/Cable)Class 0.5 / Class 0.5s (5VA – 10VA)30×10 mm busbar / 28 mm cable
Lovato DMK 3T400 A – 1500 A (Busbar)Class 0.5 / Class 0.2s (10VA – 15VA)50×12 mm / 40×40 mm busbars
Lovato DMK 4T1000 A – 4000 A (Large Busbar)Class 0.5s / Class 0.2s (15VA – 30VA)80×30 mm / 100×30 mm busbars
Split-Core CTS Series100 A – 2000 A (Retrofit)Class 0.5 / Class 1 (2.5VA – 10VA)24 mm to 80 mm square windows
Key Features

Engineering & Build Highlights

  • Class 0.2s and Class 0.5s accuracy maintained even at light loads (from 1% to 120% of rated current)
  • Sealable transparent terminal covers prevent unauthorized tampering with utility revenue connections
  • Flame-retardant self-extinguishing polycarbonate housing (UL94-V0) rated for high ambient temperatures
  • Double screw brass terminals accommodate heavy secondary wiring with zero risk of loose connections
  • Supplied with busbar mounting screws, metal base mounting brackets, and snap-on DIN-rail adaptors
  • Rated for 720 V continuous insulation voltage and 3 kV / 1 min dielectric test withstand
Applications

Target Applications & Sectors

Main LV distribution switchboard incoming & outgoing meteringMotor control centre (MCC) feeder load monitoringAutomatic power factor correction (APFC) reactive power sensingCommercial building tenant energy sub-metering retrofitsStandby generator output current & power measurementData centre branch circuit monitoring systems (BCMS)
FAQs
The CT burden (e.g. 5VA or 10VA) must exceed the total combined resistance of the secondary wiring and the connected meter input impedance. Using 2.5 mm² copper secondary wire keeps loop impedance low and ensures accuracy.
If a current transformer is energized while its secondary is open, the core saturates and induces dangerous lethal voltages (thousands of volts) across the terminals, destroying the CT insulation and endangering personnel.

Source Precision Current Transformers

Contact our sales engineers with your busbar dimensions and meter ratios for immediate stock quotation.

Discuss Your Requirement