Geared motors & mechanical drives

Estimate output speed and torque, then check mechanical fit and duty. A ratio alone does not establish a gearbox rating.

Illustrative geared motors & mechanical drives equipment
AI-generated equipment illustration.

Enable JavaScript for interactive estimates or ask our engineering team.

CHOOSE YOUR APPROACH

Start with the application.

Inline drive

Review helical arrangements where shaft alignment and continuous duty suit the machine.

Right-angle drive

Compare bevel-helical and worm layouts against efficiency, mounting and available space.

Conveyors and mixers

Account for shock, starts, overhung load, thermal rating and service factor.

BUILD A USEFUL BRIEF

Bring these details.

  • Required output speed and continuous / peak torque
  • Existing ratio, nameplate and mounting position
  • Shaft dimensions, coupling and radial / axial loads
  • Operating hours, reversals, shock and lubrication conditions
Send your project brief ↗
Does the torque estimate select a gearbox?

No. It estimates steady-state shaft torque. The manufacturer must verify service factor, peak load, thermal capacity, bearing loads and mounting.

← Explore all application hubs

COMPONENTS THAT COMPLETE THE APPLICATION

Specify the whole working system.

Start with the equipment duty. Add the control, protection and measurement functions that your project needs; these are options to review, not a pre-approved assembly.

Images are AI-generated illustrations of equipment categories, not LOVATO model photographs. Confirm dimensions and ratings from the selected model datasheet.

AI-generated illustration of the broader equipment category; not a manufacturer model

Motor protection & control

Contactors

Switch motors or other loads using the appropriate utilisation category.

Confirm: Load type and duty · coil supply · auxiliary contacts.

Compare selection details ↗

Explore all 36 component families ↗

METHODS & WORKED EXAMPLES

Understand the estimate.

These examples use the default inputs. Change the live controls above for your own scenario; the reference examples below remain fixed.

Geared motor speed & torque — worked example

Output speed = motor rpm / reduction ratio. Output torque (Nm) = 9550 × output shaft kW / output rpm.

Example inputs

  • Motor shaft power: 4 kW
  • Motor speed: 1500 rpm
  • Reduction ratio: 30 :1
  • Gear efficiency: 90 %
  • Service factor assumption: 1.5

Example result

  • Output speed: 50 rpm
  • Output torque: 687.6 Nm
  • Rated torque requirement: 1,031.4 Nm

Assumptions & limits

  • n₂ = n₁ / ratio; T₂ = 9550 × output kW / output rpm.
  • Service factor increases the required gearbox rating, not available torque.
  • Verify thermal capacity, peak torque, shock, mounting and shaft loads with the manufacturer.
  • Preliminary planning only. Final selection needs project-specific engineering verification.

Technical reference: SEW-EURODRIVE drive selection guide. This reference does not certify the website calculation or an NPE assembly.

Motor energy comparison — worked example

Annual kWh = rated shaft kW × load fraction × annual hours / efficiency fraction. Cost difference uses the entered energy tariff.

Example inputs

  • Rated shaft power: 30 kW
  • Shaft load: 75 %
  • Existing efficiency at duty: 88 %
  • Replacement efficiency at duty: 93 %
  • Annual running hours: 4000 h
  • Energy tariff assumption: 25 KES/kWh
  • Installed replacement cost: 150000 KES

Example result

  • Existing annual energy: 102,272.7 kWh
  • Replacement annual energy: 96,774.2 kWh
  • Annual cost difference: 137,463 KES

Assumptions & limits

  • Both motors deliver the same shaft duty. Use efficiency at this load, not an unrelated nameplate point.
  • Tariff is your scenario input, not a published utility rate.
  • Simple payback excludes finance, maintenance, downtime and tariff changes. Negative difference means higher operating cost.
  • Preliminary planning only. Final selection needs project-specific engineering verification.

Technical reference: US Department of Energy: motor systems guide. This reference does not certify the website calculation or an NPE assembly.

Motor starting current — worked example

Example inputs

  • Motor rating: 55 kW
  • System voltage: 415 V — industrial
  • Phase: 3Φ (three phase)
  • Starting method: Direct on line (DOL)
  • Efficiency: 92 %
  • Power factor: 0.86

Example result

  • Full load current: 96.7 A
  • Starting current: 580 A
  • Starting multiplier assumption: 6 × FLC

Assumptions & limits

  • Starting multipliers are illustrative, not measured inrush or guaranteed torque.
  • Verify motor nameplate, load acceleration, supply limits and starts per hour.
  • Preliminary planning only. Final selection needs project-specific engineering verification.