# Power factor & power quality

> Start with measured demand, power factor and harmonics. Compare correction options and prepare a clear brief for your site.

Canonical: https://nairobipower.co.ke/solutions/power-factor/
Last updated: 2026-11-10

Start with measured demand, power factor and harmonics. Compare correction options and prepare a clear brief for your site.

## Start with your operating requirements.

Record demand across the operating cycle, including light-load periods. A single bill or spot reading does not describe how correction should switch.

[Request an application review ↗](https://nairobipower.co.ke/contact/?product=Power%20factor%20%26%20power%20quality)

## Explore the equipment options.

Use these families to frame the system, then confirm the exact model and compatibility with an engineer.

[### Power Quality & Correction

Explore family ↗](https://nairobipower.co.ke/products/power-quality-correction/)[### Automatic Power Factor Correction (APFC) Banks

Explore family ↗](https://nairobipower.co.ke/products/power-quality-correction/apfc-capacitor-banks/)[### Detuned Reactor Banks

Explore family ↗](https://nairobipower.co.ke/products/power-quality-correction/detuned-reactor-banks/)[### Active Harmonic Filters & SVGs

Explore family ↗](https://nairobipower.co.ke/products/power-quality-correction/active-harmonic-filters/)

### Technical details and selection tools

[Browse shop products](https://shop.nairobipower.co.ke/products?category=Power+Quality+%26+Backup)[Explore equipment ↓](https://nairobipower.co.ke/solutions/power-factor/#equipment-options)[Open sizing tools ↓](https://nairobipower.co.ke/solutions/power-factor/#hub-tools)

## Plan the next decision.

01 / Understand the duty

### Start with the operating picture.

Record demand across the operating cycle, including light-load periods. A single bill or spot reading does not describe how correction should switch.

02 / Check the interfaces

### Gather the evidence.

Keep a record of existing capacitor steps, controller settings and harmonic measurements. Discuss correction and harmonic mitigation together.

03 / Agree the output

### Define the review you need.

Ask for a documented assessment of the measured load profile, proposed switching arrangement and commissioning checks.

## Work through a sizing scenario.

Choose a tool, replace the example inputs with site values, then save a scenario before changing your assumptions. Compare the results and include them in your project brief.

Enable JavaScript for interactive estimates or [ask our engineering team](https://nairobipower.co.ke/contact/).

## Start with the application.

### Steady inductive load

Consider fixed correction only after checking the load profile and switching arrangement.

### Variable production loads

Review an automatic stepped bank against minimum load and required response.

### Drives, UPS or distorted waveforms

Measure harmonics before choosing detuned correction or active filtering.

### Will a capacitor bank reduce every part of my bill?

No. Correction changes reactive demand; savings depend on your tariff, measured load and existing equipment. Do not assume an energy-saving percentage.

[← Explore all application hubs](https://nairobipower.co.ke/solutions/)

## Specify the whole working system.

Start with the equipment duty. Add the control, protection and measurement functions that your project needs; these are options to review, not a pre-approved assembly.

### [Power factor controllers and thyristor modules](https://nairobipower.co.ke/products/control-components/families/power-factor-controls/)

Review stepped or fast correction control against the load profile.

Confirm: Number of steps · CT arrangement · harmonic conditions.

[Compare selection details ↗](https://nairobipower.co.ke/products/control-components/families/power-factor-controls/)

### [Energy meters and power analyzers](https://nairobipower.co.ke/products/control-components/families/energy-meters/)

Measure demand and energy at useful points in the system.

Confirm: Measured circuits · accuracy needs · data integration.

[Compare selection details ↗](https://nairobipower.co.ke/products/control-components/families/energy-meters/)

### [Current transformers](https://nairobipower.co.ke/products/control-components/families/current-transformers/)

Match sensing to the meter or protection application.

Confirm: Ratio and secondary · class and burden · conductor aperture.

[Compare selection details ↗](https://nairobipower.co.ke/products/control-components/families/current-transformers/)

### [Contactors](https://nairobipower.co.ke/products/control-components/families/contactors/)

Switch motors or other loads using the appropriate utilisation category.

Confirm: Load type and duty · coil supply · auxiliary contacts.

[Compare selection details ↗](https://nairobipower.co.ke/products/control-components/families/contactors/)

### [Communication devices](https://nairobipower.co.ke/products/control-components/families/communications/)

Connect compatible devices to the required monitoring network.

Confirm: Protocol · physical interface · network architecture.

[Compare selection details ↗](https://nairobipower.co.ke/products/control-components/families/communications/)

[Explore all 36 component families ↗](https://nairobipower.co.ke/products/control-components/)

### Continue into equipment & assemblies

[Power Quality & Correction ↗](https://nairobipower.co.ke/products/power-quality-correction/)[Automatic Power Factor Correction (APFC) Banks ↗](https://nairobipower.co.ke/products/power-quality-correction/apfc-capacitor-banks/)[Detuned Reactor Banks ↗](https://nairobipower.co.ke/products/power-quality-correction/detuned-reactor-banks/)[Active Harmonic Filters & SVGs ↗](https://nairobipower.co.ke/products/power-quality-correction/active-harmonic-filters/)

## Understand the estimate.

These examples use the default inputs. Change the live controls above for your own scenario; the reference examples below remain fixed.

### Capacitor bank sizing — worked example

Required kVAr = active kW × [tan(arccos(current power factor)) − tan(arccos(target power factor))].

### Example inputs

- Active power: 400 kW
- Current power factor: 0.75
- Target power factor: 0.95
- System phase: 3Φ (three phase)
- System voltage: 415 V — industrial

### Example result

- Required correction: 221.3 kVAR
- Standard bank: 250 kVAR
- Corrected current: 586 A

### Assumptions & limits

- Capacitance: 4,090 μF per phase at 415 V, 50 Hz
- Detuning: 7 % detuned reactors (189 Hz) where harmonics are present
- Discharge: built-in resistors discharging to below 50 V within 60 s
- Where THDi exceeds 10 %, specify detuned reactors or an active harmonic filter.
- Preliminary planning only. Final selection needs project-specific engineering verification.

Technical reference: [Schneider Electric: power-factor correction selection](https://www.se.com/us/en/faqs/FA335417/). This reference does not certify the website calculation or an NPE assembly.

### kVA ↔ amps — worked example

### Example inputs

- Value: 500
- Conversion: kVA → amps
- Phase: 3Φ (three phase)
- System voltage: 415 V — industrial
- Power factor: 0.8

### Example result

- Line current: 696 A
- Apparent power: 500 kVA
- Active power: 400 kW

### Assumptions & limits

- Phase system: 3Φ balanced at 415 V
- Multiplier used: √3 × V
- Assumes a balanced, linear load profile
- Preliminary planning only. Final selection needs project-specific engineering verification.

## Bring these details.

- Recent electricity bills and interval demand data
- Measured kW, kVA, power factor and voltage
- Harmonic survey and major nonlinear loads
- Transformer rating, single-line diagram and existing bank details

[Send your project brief ↗](https://nairobipower.co.ke/contact/?product=Power%20factor%20%26%20power%20quality)

## Related equipment & services

[Power Quality & Correction ↗](https://nairobipower.co.ke/products/power-quality-correction/)[Automatic Power Factor Correction (APFC) Banks ↗](https://nairobipower.co.ke/products/power-quality-correction/apfc-capacitor-banks/)[Detuned Reactor Banks ↗](https://nairobipower.co.ke/products/power-quality-correction/detuned-reactor-banks/)[Active Harmonic Filters & SVGs ↗](https://nairobipower.co.ke/products/power-quality-correction/active-harmonic-filters/)

## Connect your application to the right components.

Explore these related component families, compare exact manufacturer references and build a quotation request.

[Open the E-Shop](https://shop.nairobipower.co.ke/products?category=Power+Quality+%26+Backup)

LOVATO manufacturer family images; exact configurations vary by model.

[Send a BOQ or parts list](https://shop.nairobipower.co.ke/bulk-order)

## Continue the specification

### Application and selection guides

- [Harmonic assessment](https://nairobipower.co.ke/solutions/harmonic-assessment/)
- [Power-quality equipment selection](https://nairobipower.co.ke/products/power-quality-correction/selection-guide/)

### Related engineering methods

- [Capacitor-bank resonance screen](https://nairobipower.co.ke/tools/capacitor-resonance/)
- [Third-harmonic neutral current](https://nairobipower.co.ke/tools/neutral-harmonics/)