# Electric motors

> Match the motor to its load, mounting and duty. Compare energy use using your operating hours and tariff before considering a replacement.

Canonical: https://nairobipower.co.ke/solutions/motors/
Last updated: 2026-11-10

Match the motor to its load, mounting and duty. Compare energy use using your operating hours and tariff before considering a replacement.

## Start with your operating requirements.

Start with the driven machine and duty cycle. Record speed, mounting, shaft dimensions, supply and the conditions around the motor.

[Request an application review ↗](https://nairobipower.co.ke/contact/?product=Electric%20motors)

## Explore the equipment options.

Use these families to frame the system, then confirm the exact model and compatibility with an engineer.

[### Industrial Electric Motors

Explore family ↗](https://nairobipower.co.ke/products/electric-motors/)[### IE3 Premium Efficiency Motors

Explore family ↗](https://nairobipower.co.ke/products/electric-motors/ie3-premium-efficiency-motors/)[### Three-Phase Induction Motors

Explore family ↗](https://nairobipower.co.ke/products/electric-motors/three-phase-induction-motors/)[### Single-Phase Electric Motors

Explore family ↗](https://nairobipower.co.ke/products/electric-motors/single-phase-motors/)

### Technical details and selection tools

[Browse shop products](https://shop.nairobipower.co.ke/products?category=Industrial+Control)[Explore equipment ↓](https://nairobipower.co.ke/solutions/motors/#equipment-options)[Open sizing tools ↓](https://nairobipower.co.ke/solutions/motors/#hub-tools)

## Plan the next decision.

01 / Understand the duty

### Start with the operating picture.

Start with the driven machine and duty cycle. Record speed, mounting, shaft dimensions, supply and the conditions around the motor.

02 / Check the interfaces

### Gather the evidence.

A replacement should be checked for mechanical fit as well as electrical rating. Capture photographs of the nameplate, terminal arrangement and coupling.

03 / Agree the output

### Define the review you need.

Request a comparison covering fit, operating duty, protection and commissioning requirements, with energy assumptions stated separately.

## Work through a sizing scenario.

Choose a tool, replace the example inputs with site values, then save a scenario before changing your assumptions. Compare the results and include them in your project brief.

Enable JavaScript for interactive estimates or [ask our engineering team](https://nairobipower.co.ke/contact/).

## Start with the application.

### Like-for-like replacement

Check frame, shaft, flange, speed, voltage and mounting dimensions before ordering.

### Long running hours

Compare efficiencies at the actual load, alongside installed cost and downtime.

### Drive-fed applications

Check insulation, bearing protection, cooling and the permitted speed range.

### Is matching kW enough for a replacement?

No. Speed, torque, mounting, supply, starting method, duty and environmental requirements must also match.

[← Explore all application hubs](https://nairobipower.co.ke/solutions/)

## Specify the whole working system.

Start with the equipment duty. Add the control, protection and measurement functions that your project needs; these are options to review, not a pre-approved assembly.

### [Motor protection circuit breakers](https://nairobipower.co.ke/products/control-components/families/motor-breakers/)

Protect individual motor circuits as part of a coordinated starter.

Confirm: Motor full-load current · fault level · starter coordination.

[Compare selection details ↗](https://nairobipower.co.ke/products/control-components/families/motor-breakers/)

### [Motor protection relays](https://nairobipower.co.ke/products/control-components/families/overload-relays/)

Monitor overload conditions within the motor protection scheme.

Confirm: Motor current · trip class · reset strategy.

[Compare selection details ↗](https://nairobipower.co.ke/products/control-components/families/overload-relays/)

### [Monitoring relays](https://nairobipower.co.ke/products/control-components/families/monitoring-relays/)

Identify phase, voltage or current conditions that need an alarm or trip.

Confirm: Monitored quantity · operating window · reset behaviour.

[Compare selection details ↗](https://nairobipower.co.ke/products/control-components/families/monitoring-relays/)

### [Switch disconnectors](https://nairobipower.co.ke/products/control-components/families/disconnectors/)

Plan an appropriate isolation point for equipment and maintenance.

Confirm: AC or DC duty · pole arrangement · locking requirements.

[Compare selection details ↗](https://nairobipower.co.ke/products/control-components/families/disconnectors/)

[Explore all 36 component families ↗](https://nairobipower.co.ke/products/control-components/)

### Continue into equipment & assemblies

[Industrial Electric Motors ↗](https://nairobipower.co.ke/products/electric-motors/)[IE3 Premium Efficiency Motors ↗](https://nairobipower.co.ke/products/electric-motors/ie3-premium-efficiency-motors/)[Three-Phase Induction Motors ↗](https://nairobipower.co.ke/products/electric-motors/three-phase-induction-motors/)[Single-Phase Electric Motors ↗](https://nairobipower.co.ke/products/electric-motors/single-phase-motors/)

## Understand the estimate.

These examples use the default inputs. Change the live controls above for your own scenario; the reference examples below remain fixed.

### Motor energy comparison — worked example

Annual kWh = rated shaft kW × load fraction × annual hours / efficiency fraction. Cost difference uses the entered energy tariff.

### Example inputs

- Rated shaft power: 30 kW
- Shaft load: 75 %
- Existing efficiency at duty: 88 %
- Replacement efficiency at duty: 93 %
- Annual running hours: 4000 h
- Energy tariff assumption: 25 KES/kWh
- Installed replacement cost: 150000 KES

### Example result

- Existing annual energy: 102,272.7 kWh
- Replacement annual energy: 96,774.2 kWh
- Annual cost difference: 137,463 KES

### Assumptions & limits

- Both motors deliver the same shaft duty. Use efficiency at this load, not an unrelated nameplate point.
- Tariff is your scenario input, not a published utility rate.
- Simple payback excludes finance, maintenance, downtime and tariff changes. Negative difference means higher operating cost.
- Preliminary planning only. Final selection needs project-specific engineering verification.

Technical reference: [US Department of Energy: motor systems guide](https://www.energy.gov/sites/prod/files/2014/04/f15/amo_motors_guidebook_web.pdf). This reference does not certify the website calculation or an NPE assembly.

### Motor starting current — worked example

### Example inputs

- Motor rating: 55 kW
- System voltage: 415 V — industrial
- Phase: 3Φ (three phase)
- Starting method: Direct on line (DOL)
- Efficiency: 92 %
- Power factor: 0.86

### Example result

- Full load current: 96.7 A
- Starting current: 580 A
- Starting multiplier assumption: 6 × FLC

### Assumptions & limits

- Starting multipliers are illustrative, not measured inrush or guaranteed torque.
- Verify motor nameplate, load acceleration, supply limits and starts per hour.
- Preliminary planning only. Final selection needs project-specific engineering verification.

### Geared motor speed & torque — worked example

Output speed = motor rpm / reduction ratio. Output torque (Nm) = 9550 × output shaft kW / output rpm.

### Example inputs

- Motor shaft power: 4 kW
- Motor speed: 1500 rpm
- Reduction ratio: 30 :1
- Gear efficiency: 90 %
- Service factor assumption: 1.5

### Example result

- Output speed: 50 rpm
- Output torque: 687.6 Nm
- Rated torque requirement: 1,031.4 Nm

### Assumptions & limits

- n₂ = n₁ / ratio; T₂ = 9550 × output kW / output rpm.
- Service factor increases the required gearbox rating, not available torque.
- Verify thermal capacity, peak torque, shock, mounting and shaft loads with the manufacturer.
- Preliminary planning only. Final selection needs project-specific engineering verification.

Technical reference: [SEW-EURODRIVE drive selection guide](https://download.sew-eurodrive.com/download/pdf_u/30592232.pdf). This reference does not certify the website calculation or an NPE assembly.

## Understand the estimate.

These examples use the default inputs. Change the live controls above for your own scenario; the reference examples below remain fixed.

### Three-phase voltage unbalance — worked example

### Example inputs

- L1–L2 voltage: 415 V
- L2–L3 voltage: 410 V
- L3–L1 voltage: 420 V

### Example result

- Average line voltage: 415 V
- Maximum deviation: 5 V
- Voltage unbalance: 1.2 %

### Assumptions & limits

- Unbalance (%) = 100 × maximum absolute deviation from the average / average.
- Use line-to-line readings taken under the same operating condition.
- No pass/fail limit or trip delay is selected. Check equipment limits and investigate supply conditions with a qualified engineer.
- This method uses voltage magnitudes only; it is not an IEC negative-sequence calculation.
- Preliminary planning only. Final selection needs project-specific engineering verification.

Method reference: [US DOE — Energy Management for Motor-Driven Systems](https://www.energy.gov/sites/prod/files/2014/04/f15/NN0116.pdf)

## Bring these details.

- Clear nameplate and mounting photographs
- Rated kW, rpm, voltage, current and duty
- Frame, shaft and flange dimensions
- Load profile, hours, ambient temperature and ingress protection

[Send your project brief ↗](https://nairobipower.co.ke/contact/?product=Electric%20motors)

## Related equipment & services

[Industrial Electric Motors ↗](https://nairobipower.co.ke/products/electric-motors/)[IE3 Premium Efficiency Motors ↗](https://nairobipower.co.ke/products/electric-motors/ie3-premium-efficiency-motors/)[Three-Phase Induction Motors ↗](https://nairobipower.co.ke/products/electric-motors/three-phase-induction-motors/)[Single-Phase Electric Motors ↗](https://nairobipower.co.ke/products/electric-motors/single-phase-motors/)

## Connect your application to the right components.

Explore these related component families, compare exact manufacturer references and build a quotation request.

[Open the E-Shop](https://shop.nairobipower.co.ke/products?category=Industrial+Control)

LOVATO manufacturer family images; exact configurations vary by model.

[Send a BOQ or parts list](https://shop.nairobipower.co.ke/bulk-order)

## Continue the specification

### Application and selection guides

- [Motor starter selection guide](https://nairobipower.co.ke/products/motor-control-automation/starter-selection-guide/)

### Related engineering methods

- [Motor starting current](https://nairobipower.co.ke/tools/motor-starting/)
- [DC control power budget](https://nairobipower.co.ke/tools/control-power/)