# EV Charging Solutions

> Commercial and residential EV charging stations, Mode 3 AC chargers, DC fast chargers and load management — Nairobi Power Engineers.

Canonical: https://nairobipower.co.ke/products/cables-wiring/ev-charging/
Last updated: 2026-11-10

Mode 3 AC chargers and DC ultra-fast charging stations engineered to BS 7671 Section 722 and IEC 61851

### Equipment & Range Highlights

  Commercial & Domestic • 7.4kW – 22kW

### Smart AC EV Wallboxes (Mode 3 Type 2)

Power7.4 kW (1-Ph) / 22 kW (3-Ph)

SocketType 2 Shuttered (IEC 62196)

ProtectionBuilt-in 6mA DC RDC-DD

Single-phase (7.4 kW) and three-phase (22 kW) smart AC charging wallboxes with RFID user access, dynamic load balancing, and OCPP cloud billing.

  Fleet & Public Highway • 30kW – 240kW

### Commercial DC Fast Charging Stations

Capacity30 kW to 240 kW DC

ConnectorsDual CCS2 / CHAdeMO

ProtocolOCPP 1.6J / 2.0.1 Cloud

High-power DC rapid chargers with dual CCS2 charging guns, liquid-cooled power modules, 10-inch touchscreens, and credit card payment terminals.

### Technical details and selection tools

### Search and refine this range

## Electric Vehicle (EV) Charging Solutions

As electric mobility accelerates across East Africa with electric buses, commercial fleets, and private EVs, dependable charging infrastructure is crucial. Nairobi Power Engineers designs, supplies, installs and commissions turnkey Electric Vehicle Supply Equipment (EVSE) for commercial plazas, residential developments, and fleet depots.

Engineered strictly in compliance with BS 7671:2018+A2:2022 (Section 722) and IEC 61851 standards, our EV charging stations feature Type 2 Mode 3 AC wallboxes (7.4 kW to 22 kW) and DC fast chargers (30 kW to 240 kW CCS2) with built-in Type B 6mA DC leakage protection, open-PEN fault detection, and OCPP 1.6/2.0 smart billing integration.

### EV Charging Technical Reference

| Parameter | AC Smart Wallbox (7.4kW / 22kW) | DC Fast Charger (60kW – 240kW) |
| --- | --- | --- |
| Charging Mode & Standard | Mode 3 (IEC 61851-1 / BS 7671 Sec 722) | Mode 4 DC Rapid (IEC 61851-23 / 24) |
| Electrical Input | 230V 1-Ph 32A / 400V 3-Ph 32A (50 Hz) | 400 V AC 3-Phase + Neutral (50 Hz) |
| Connector Interfaces | Type 2 Socket / Tethered 5m Cable (IEC 62196) | Dual CCS Combo 2 Guns (Heavy Duty Flexible) |
| DC Residual Protection | Internal 6 mA DC RDC-DD + Type A 30mA RCBO | Complete galvanic isolation & continuous insulation monitoring |
| Smart Load Management | Dynamic load balancing with building master meter | Matrix power sharing across dual charging guns |
| Enclosure & Protection | IP54 / IP65 • IK10 Vandal-Resistant Polycarb/Steel | IP54 Heavy Outdoor Powder-Coated Steel Kiosk |

### Engineering & Build Highlights

- Built-in 6mA DC residual direct current detecting device (RDC-DD) eliminates the need for expensive external Type B RCDs
- Open-PEN conductor fault protection conforms to BS 7671 Section 722 without requiring separate earth rods on PME supplies
- Dynamic Load Balancing (DLB): throttles charging speed automatically to prevent tripping the building main transformer
- OCPP 1.6J / 2.0.1 compliant: connects with M-Pesa mobile payment platforms and third-party EV charging network operators
- Solar EV charging integration: charges vehicles exclusively from surplus rooftop solar power generation
- RFID card authentication and smartphone app control with automated billing and session reporting

### Target Applications & Sectors

 Commercial shopping malls & office parking complexesElectric bus, delivery van & taxi fleet charging depotsHighway service stations & rest stops across KenyaResidential apartment blocks & private residential villasHotel resorts & hospitality valet parking amenitiesCorporate headquarters employee vehicle charging bays

#### In This Family

#### Get A Quotation

Call +254 737 944 014 or send a project brief for current pricing and lead time.

 [Request A Quote](https://nairobipower.co.ke/contact/)

On PME (TN-C-S) utility grids, a broken neutral wire can energize the vehicle metal chassis to 230V, creating a deadly electrocution hazard. Open-PEN protection detects supply unbalance and instantly isolates all phases, neutral, and earth in < 4 seconds.

A 22 kW AC charger adds approx. 100–120 km of range per hour (ideal for 3–4 hour office/mall parking). A 120 kW DC fast charger charges an EV battery from 10% to 80% in just 20 to 30 minutes.

[Open sizing tools ↓](https://nairobipower.co.ke/products/cables-wiring/ev-charging/#product-estimate)[Enquire about this application ↗](https://nairobipower.co.ke/contact/?product=EV%20Charging%20Solutions)

### Deploy EV Charging Stations

Contact our e-mobility infrastructure engineers for site load assessments, charger sizing, and turnkey installation.

 [Discuss Your Requirement](https://nairobipower.co.ke/contact/)

## EV Charging Solutions in context

Conceptual engineering illustration. Confirm the exact equipment, ratings and configuration against your application before ordering.

[Discuss your configuration](https://nairobipower.co.ke/contact/)

## Explore your requirements.

Try the tools relevant to ev charging solutions, compare scenarios, then send the inputs to our team.

Enable JavaScript for live calculations, or [ask our engineering team](https://nairobipower.co.ke/contact/).

## Connect your application to the right components.

Explore these related component families, compare exact manufacturer references and build a quotation request.

[Open the E-Shop](https://shop.nairobipower.co.ke/products?category=Circuit+Protection)

LOVATO manufacturer family images; exact configurations vary by model.

[Send a BOQ or parts list](https://shop.nairobipower.co.ke/bulk-order)

## Continue the specification

### Application and selection guides

- [Cable and protection selection](https://nairobipower.co.ke/products/cables-wiring/selection-guide/)

### Related engineering methods

- [Cable sizing](https://nairobipower.co.ke/tools/cable-sizing/)
- [Radial feeder fault current](https://nairobipower.co.ke/tools/feeder-fault-current/)