# Engineering Knowledge

> Practical guides to power quality, motor control, metering and low-voltage switchgear selection.

Canonical: https://nairobipower.co.ke/knowledge/
Last updated: 2026-11-10

Practical guides to power quality, motor control, metering and low-voltage switchgear selection.

Use these guides to prepare a specification, understand the selection checks and identify what needs engineering review. Calculators provide preliminary estimates; confirm the final equipment and assembly requirements for your project.

## Explore the engineering guides

### [APFC Panels in Kenya](https://nairobipower.co.ke/knowledge/apfc-panels-kenya/)

An automatic power factor correction panel switches capacitor stages to follow changing reactive demand. Specify its correction capacity, step sizes and harmonic suitability from measurements across the operating cycle. A panel cannot be selected responsibly from the incoming breaker rating or the total motor nameplate power alone.

### [KPLC Power Factor Penalty in Kenya](https://nairobipower.co.ke/knowledge/kplc-power-factor-penalty/)

To assess a Kenya Power power-factor charge, identify the tariff category and operative tariff clause on the account, then compare them with the billed measurements. Capacitor correction can reduce fundamental reactive demand, but this page does not assert an unverified current threshold, surcharge rate or saving for a customer account.

### [Motor Control Centres in Kenya](https://nairobipower.co.ke/knowledge/motor-control-centre-kenya/)

A motor control centre groups motor feeders, starting equipment, protection and controls into an assembly. Specify it from the load schedule, starting duty, available fault current and operating requirements, then establish the applicable IEC 61439 design and routine verification evidence. Component brands alone do not establish the rating of the complete MCC.

### [Capacitor Bank Sizing in Kenya](https://nairobipower.co.ke/knowledge/capacitor-bank-sizing-kenya/)

Size a capacitor bank from measured active power and the change in displacement power factor: Qc = P × [tan(arccos PF1) − tan(arccos PF2)]. The result is fundamental-frequency correction in kvar at one operating point. Stage arrangement, harmonics, voltage and protection still require separate selection.

### [Detuned Reactor vs Standard Capacitor Bank](https://nairobipower.co.ke/knowledge/detuned-reactor-vs-standard-capacitor-bank/)

A plain capacitor bank supplies fundamental reactive power without a series reactor. A detuned bank combines reactors and capacitors to control the branch impedance and reduce harmful resonance exposure. Choose between them from the measured harmonic spectrum and network impedance; detuning is not a universal cure for harmonic distortion.

### [Active vs Passive Harmonic Filters](https://nairobipower.co.ke/knowledge/active-vs-passive-harmonic-filter/)

An active harmonic filter injects controlled compensating current, while a passive filter uses an impedance network to redirect selected harmonic currents. Selection depends on the spectrum, load variation, supply impedance and required assessment point. Neither technology guarantees a particular distortion result without a system-specific design.

### [Power Quality Audit in Kenya](https://nairobipower.co.ke/knowledge/power-quality-audit-kenya/)

A power quality audit records electrical behaviour against operating events to identify the cause of a defined problem. Agree the measurement locations, quantities, operating cycle and reporting method before installing instruments. A short spot reading cannot establish how an intermittent disturbance behaves during unobserved production or supply conditions.

### [MCC Form 2, Form 3 and Form 4: What Is the Difference?](https://nairobipower.co.ke/knowledge/mcc-form-2-3-4-difference/)

Internal separation describes barriers between an assembly’s busbars, functional units and external-conductor terminals. Form 2 separates busbars from functional units; Form 3 also separates functional units; Form 4 adds separation between the external-conductor terminals associated with different units. The selected subform defines the terminal arrangement. None of these labels alone permits live working.

### [DOL, Star-Delta, Soft Starter or VFD?](https://nairobipower.co.ke/knowledge/dol-star-delta-soft-starter-vfd/)

Choose the starting method from required accelerating torque, supply disturbance, starting frequency and speed-control needs. DOL applies the supply directly; star-delta temporarily reduces winding voltage; a soft starter controls applied voltage during starting; a VFD controls frequency and voltage. Check the actual motor and driven load rather than selecting solely by motor size.

### [IE3 Motors in Kenya: Selection and Energy Payback](https://nairobipower.co.ke/knowledge/ie3-motors-kenya/)

IE3 identifies a motor efficiency class within the IEC framework for line-operated AC motors. It is not a single efficiency percentage or a guarantee of system savings. Compare the candidate motors at the required shaft duty, annual operating hours and verified energy cost, while checking that their mechanical and electrical characteristics suit the machine.

### [Meter Boards in Kenya: Direct and CT Metering](https://nairobipower.co.ke/knowledge/meter-boards-kenya/)

A meter board accommodates metering equipment and the associated connection, isolation and protection arrangements. Specify the number of supplies, direct or CT measurement, meter interfaces and the utility or project requirements before fixing its layout. A tenant count alone cannot determine cable space, CT characteristics or acceptance of the completed arrangement.

### [LV Switchgear Manufacturer in Kenya: How to Specify an Assembly](https://nairobipower.co.ke/knowledge/lv-switchgear-manufacturer-kenya/)

An LV switchgear manufacturer should define the complete assembly’s ratings, operating conditions and applicable verification evidence, not only list the installed components. For an IEC 61439 specification, distinguish design verification from routine verification and identify the offered configuration. Nairobi Power Engineers is an LV switchgear manufacturer and supplier established in 1984, based in Nairobi.

## Continue your specification

[Explore equipment ranges](https://nairobipower.co.ke/products/) · [Engineering calculators](https://nairobipower.co.ke/tools/) · [Discuss your requirements](https://nairobipower.co.ke/contact/)